Wednesday 11 September 2019

Comparing 40G and 100G Transceivers modules

by www.fiber-mart.com

As things stand, the trend for high-speed data transmission and high-bandwidth is overwhelming.

now, whether you believe it or not, prepared or not prepared, 40G and 100G have already on the way. To upgrade to 40G or skip it and directly migrate to 100G has become a question for many data center mangers and IT engineers

The growth in 100G comes at the expense of 10G and 40G interfaces. Infonetics says that 10G in carrier networks “is beginning a long decline after an epic 15-year run.”Meanwhile, the market for 40G is “vaporizing,” according to the market research firms.“40G transceivers are ramping up hard as data centers deploy 40GbE, particularly as a high-density 10G interface via breakout cables. 40G QSFP demand growth over single-mode fiber is primarily a result of large shipments to Internet content providers Microsoft and Google,” said Andrew Schmitt, research director for carrier transport networking at IHS Infonetics.

40G and 100G Transceiver Technical Features


40G and 100G have two main types in the data center. Short reach (SR4) for ~100 meters transmission on multimode fiber and Long Reach (LR4) for 100 meters to 10km using single-mode fiber. We can use SR/LR transceivers to connect compute clusters and various switches layers in data centers. 40G transceivers are typically deployed as four 10G lanes in QSFP or CFP MSAs. 40G SR transceiver uses 8 multi-mode fibers, VCSEL lasers, and the QSFP MSA. Using edge-emitting lasers and multiplexes the four 10G lanes onto two single-mode fibers, 40G LR4 reach a 10km distance per CFP MSA, CFP/2 or QSFP28 MSAs. The 40G SR4 and LR4 transceivers can be used in the same QSFP switch port without any issues.

40G,In today’s market, 40G products mainly include 40GBASE-SR4 and 40GBASE-LR4 QSFP+ modules and 40G AOCs. QSFP+ supports both 40G links between racks and high-density 10G links within the rack, especially the 40G QSFP+ breakout AOC which is an ideal solution for 40G migration.“40G transceivers are ramping up hard as data centers deploy 40GbE, particularly as a high-density 10G interface via breakout cables. 40G QSFP demand growth over single-mode fiber is primarily a result of large shipments to internet content providers Microsoft and Google,”said Andrew Schmitt.

100G SR10 transceivers use 20 multi-mode fibers, VCSELs and the CXP MSA, the 100G LR4 transceivers uses CFP form and 2 single-mode fibers.The market for 100G data center optics is accelerating, but it has yet to be turbocharged by widespread data center deployment in the way 40G QSFP optics have.

The market for 100G data center optics is accelerating, but it has yet to be turbocharged by widespread data center deployment in the way 40G QSFP optics have.The data center likely will be the engine of any overall growth in optical transceiver sales over the next several years. Data centers now represent 65% of the overall telecom and datacom market for 10G/40G/100G optical transceivers. 

100G is ready here. Tens of thousands of 100G Ethernet links deployed in core routers and carrier switches. Vast majority are CFP modules and CFP2 deployments are now starting. In addition,100G is rapidly expanding. For instance, new optical standards for the data center (100G SR4, CWDM4, PSM4) and new higher density100G module form factors like CFP4 and QSFP28 are on the way. High port-count 100G switches are being designed and many 100G modules will be used to support high-density 10G and 25G. It is said that 100G and 4x 25G deployments are expected to grow substantially starting in 2015. 100G products mainly include 100GBASE-SR10 and 100G LR4 CFP/CFP2/CFP4 and 120G AOCs. Additionally, QSFP28 as the 100G module form factor of choice for new data center switches is also launched.

Why not 40G?

If you ask me why 40G Ethernet will be obsolete? The short answer is “cost”. From the technical point, The primary issue lies in the fact that 40G Ethernet uses 4x10G signalling lanes. On UTP, 40G uses 4 pairs at 10G each. Early versions of the 40G standard used 4 pairs, but rapid advances in manufacturing developed a 4x10G WDM on a single fiber optic pair. Each 40G SFP module contains a silicon chip that performs multiplexing so that the switch see 40 gigabits in and 40 gigabits out. It’s similar to Coarse Wave Division Multiplexing when using fiber. When you buy a 40G cable or QSFP, you are paying for the cost of the chip and software, plus the lasers, etc. When using 25/50/100G, the “lane speed” is increased to 25 gigabits per second. For 100G Ethernet, there are four 25G signalling lanes. It’s cheaper to buy 100G with four lanes rather than 40G with a four-lane MUX.

40G/100G transceivers development supports this growth with smaller module form factors for higher port density, lower power consumption per bit and lower cost per bit.

Fiber-MART offers several 40G and 100G Transceiver modules to support the transmission of very high-speed digital signals, providing a bandwidth of 40G or 100G, with distances reaching up to 40 kilometers. These include 40G CFP transceiver and 100G CFP transceivers as well as 40G QSFP+ transceivers. For more informations, you can visit www.fiber-mart.com.pls feel free to contact us for any question. E-mail : service@fiber-mart.com