Sunday, 16 September 2018

12 Fibers 10G OM4 12 Strands MTP Harness Cable 3.0mm LSZH/Riser

FM SKU#:SKU0077A2
Model#:FM12OM4-2MTPX-x
MFG PART#:

12 Fibers, MTP to LC/SC/ST/FC,10G OM4, 12 Standard - MTP Breakout Harness Cable

MTP is the high dense degree of optical fiber pre-connect system,which is generally use in three areas:
  • The data centra application with high dense degree environment
  • The optical fiber to the building
  • The internal connector application in fiber equipment such as Splitter, 40G /100G SFP and SFP+.


  • Fiber-Mart's MTP fiber patch cable is compliant to IEC-61754-7 and TIA-604-5(FOCIS-5) standard. It can be widely used for

Fiber-MART.Com pdf_d.png10G upgrade to 40G/100G data center.

MTP Connector

MTP Male with PinsMTP Female without Pins
Two other clearly visible features are the noses and guide grooves (keys) on the top side. The Female and Male need to be used together.

Pre-terminated MTP Technology-Polarity Type B (Cross)




The application above is for the MTP-LC harness cable connecting a QSFP+ port to (4)SFP+ ports directly.

In many existing DC environments, LC-MTP cables are used to support high density fiber trunks between switches, rack patch panels and main distribution cabling panels (MDA).

For example:

The above is the Eight-Fiber MTP-LC Assembly uses a pinless connector on one end for interfacing with the QSFP port on the Cisco Nexus 6000series, The other end contains four LC uniboot connectors, which provide connectivity to the SFP+ ports on the switch. The polarity of the assembly pairs the fibers from the MTP Connector from the outside to the inside; thus, fiber 1 and fiber 12 are a duplex pair, as are fiber 2 and fiber 11, etc.

MTP&MPO Difference


The term MTP is a registered trademark of US Conec, which have became the tendency in Europe&American fiber communications areas at present.

Assembly Structure Illustration


12-Fiber Mini-Core Cable structure
MTP Hybrid Harnesses Fiber Patch Cables are terminated with MTP connector on one end and other end with LC, FC, SC, ST, or MTRJ connectors to meet a variety of fiber cabling requirements.
1.The default diameter of the MTP cable is 3.0mm.
2.The diameter of branch cable could be choose as 0.9mm,2.0mm,please kindly contact us at sales@fiber-mart.com for other diameter standard.
3.Fiber-Mart can also custom the pulling eyes, welcome to contact us if you need.

MTP/MPO Machinery & Testing Equipment




Fiber-MART.Com fs-Machinery-Testing-Equipment-01.jpg
1Our adopt industry's leading high-performance polishing machine, and complemented by precision plates holders designed for MT ferrules.
 
2The industry leading device of 3D interferometer provides verification of MTP/MPO polishing process, the interferometer making all parameters of hte polished MT ferrule complies and exceeds industry standards.
 
3After the 3D interference detection, the flexibility of the tester provides the the complete spectrum of optical testing required for complex and high fiber count cable assemblies.


Fiber-MART.Com fs-Machinery-Testing-Equipment-02.jpg

MTP Termination

TypeSingle modeSingle modeMulti mode
(APC polish)(PC polish)(PC polish)
Fiber count8, 12, 24 etc.8, 12, 24 etc.8, 12, 24 etc.
Fiber typeG652D, G657A1 etc.G652D, G657A1 etc.OM1, OM2, OM3 etc.
Maximum Insertion LossEliteStandardEliteStandardEliteStandard
Low LossLow LossLow Loss
≤0.35 dB≤0.70 dB≤0.35 dB≤0.70 dB≤0.35dB≤0.60dB
Return Loss≥60 dB≥60 dBN/A
Durability≥500 times≥500 times≥500 times
Operating Temperature-40℃ ~ +80℃-40℃~ +80℃-40℃~ +80℃
Test Wavelength1310nm1310nm850nm

Common Termination

TypeSingle modeMulti mode
(UPC APC polish)(UPC polish)
Insertion Loss≤0.30dB≤0.30dB
Return Loss≥55 dB≥60 dB≥25 dB
Durability≥1000 times≥1000 times
Operating Temperature-40℃ ~ +80℃-40℃ ~ +80℃
Test Wavelength1310nm850nm



Note: Maximum Bandwidths of Different Multimode Fibers
OM1 – 62.5 um Core – 10GBit up to 33 meters, gigabit up to 300m
OM2 – 50 um Core – 10GBit up to 82 meters,gigabit up to 500m
OM3 – 50 um Core, Laser Optimized – 10GBit up to 300 meters,gigabit up to 1000m
OM4 – 50 um Core, Laser Optimized – 10GBit up to 550 meters,gigabit up to 1000m

Make To Order

Fiber TypeFiber StandardFiber CountCable TypeTerminationCable Length(m)Breakout Length 1&2(Inches)Breakout TerminationPolish Type
OM4
OM3
OS1/2
OM2
OM1
12 Fibers8~144 FibersLSZH Bunch
LSZH Ribbon
Riser Bunch
Riser Ribbon
First Connector:
MTP Female
MTP Male
1~99912~99
(36" is typical)
3.0mmUPC
APC
24 Fibers24~144 FibersSecond Connector:
LC Duplex/LC Simplex
SC Duplex/SC Simplex
ST Duplex/ST Simplex
FC Duplex/FC Simplex
0.9μm (standard)
2.0mm
3.0mm


Note:Polishing connector (A): PC (multimode), APC 8° (single-mode)
Polishing connector (B) : PC (multimode/single-mode), APC 8° (single-mode)
Furcation length (B): 0.5m/0.3m for 1m total length
Type of protection connector: IP20
Patch cord Type: Minicore cable, round