FM SKU#:SKU0077A2
Model#:FM12OM4-2MTPX-x
MFG PART#:
Model#:FM12OM4-2MTPX-x
MFG PART#:
12 Fibers, MTP to LC/SC/ST/FC,10G OM4, 12 Standard - MTP Breakout Harness Cable
MTP is the high dense degree of optical fiber pre-connect system,which is generally use in three areas:
- The data centra application with high dense degree environment
- The optical fiber to the building
- The internal connector application in fiber equipment such as Splitter, 40G /100G SFP and SFP+.
Fiber-Mart's MTP fiber patch cable is compliant to IEC-61754-7 and TIA-604-5(FOCIS-5) standard. It can be widely used for
10G upgrade to 40G/100G data center.
MTP Connector
MTP Male with Pins | MTP Female without Pins |
Two other clearly visible features are the noses and guide grooves (keys) on the top side. The Female and Male need to be used together. |
Pre-terminated MTP Technology-Polarity Type B (Cross)
The application above is for the MTP-LC harness cable connecting a QSFP+ port to (4)SFP+ ports directly.
In many existing DC environments, LC-MTP cables are used to support high density fiber trunks between switches, rack patch panels and main distribution cabling panels (MDA).
For example:
The above is the Eight-Fiber MTP-LC Assembly uses a pinless connector on one end for interfacing with the QSFP port on the Cisco Nexus 6000series, The other end contains four LC uniboot connectors, which provide connectivity to the SFP+ ports on the switch. The polarity of the assembly pairs the fibers from the MTP Connector from the outside to the inside; thus, fiber 1 and fiber 12 are a duplex pair, as are fiber 2 and fiber 11, etc.
MTP&MPO Difference
The term MTP is a registered trademark of US Conec, which have became the tendency in Europe&American fiber communications areas at present.
Assembly Structure Illustration
12-Fiber Mini-Core Cable structure
MTP Hybrid Harnesses Fiber Patch Cables are terminated with MTP connector on one end and other end with LC, FC, SC, ST, or MTRJ connectors to meet a variety of fiber cabling requirements.
1.The default diameter of the MTP cable is 3.0mm.
2.The diameter of branch cable could be choose as 0.9mm,2.0mm,please kindly contact us at sales@fiber-mart.com for other diameter standard.
3.Fiber-Mart can also custom the pulling eyes, welcome to contact us if you need.
MTP Hybrid Harnesses Fiber Patch Cables are terminated with MTP connector on one end and other end with LC, FC, SC, ST, or MTRJ connectors to meet a variety of fiber cabling requirements.
1.The default diameter of the MTP cable is 3.0mm.
2.The diameter of branch cable could be choose as 0.9mm,2.0mm,please kindly contact us at sales@fiber-mart.com for other diameter standard.
3.Fiber-Mart can also custom the pulling eyes, welcome to contact us if you need.
MTP/MPO Machinery & Testing Equipment
1 | Our adopt industry's leading high-performance polishing machine, and complemented by precision plates holders designed for MT ferrules. |
2 | The industry leading device of 3D interferometer provides verification of MTP/MPO polishing process, the interferometer making all parameters of hte polished MT ferrule complies and exceeds industry standards. |
3 | After the 3D interference detection, the flexibility of the tester provides the the complete spectrum of optical testing required for complex and high fiber count cable assemblies. |
MTP Termination
Type | Single mode | Single mode | Multi mode | |||
(APC polish) | (PC polish) | (PC polish) | ||||
Fiber count | 8, 12, 24 etc. | 8, 12, 24 etc. | 8, 12, 24 etc. | |||
Fiber type | G652D, G657A1 etc. | G652D, G657A1 etc. | OM1, OM2, OM3 etc. | |||
Maximum Insertion Loss | Elite | Standard | Elite | Standard | Elite | Standard |
Low Loss | Low Loss | Low Loss | ||||
≤0.35 dB | ≤0.70 dB | ≤0.35 dB | ≤0.70 dB | ≤0.35dB | ≤0.60dB | |
Return Loss | ≥60 dB | ≥60 dB | N/A | |||
Durability | ≥500 times | ≥500 times | ≥500 times | |||
Operating Temperature | -40℃ ~ +80℃ | -40℃~ +80℃ | -40℃~ +80℃ | |||
Test Wavelength | 1310nm | 1310nm | 850nm |
Common Termination
Type | Single mode | Multi mode | |
(UPC APC polish) | (UPC polish) | ||
Insertion Loss | ≤0.30dB | ≤0.30dB | |
Return Loss | ≥55 dB | ≥60 dB | ≥25 dB |
Durability | ≥1000 times | ≥1000 times | |
Operating Temperature | -40℃ ~ +80℃ | -40℃ ~ +80℃ | |
Test Wavelength | 1310nm | 850nm |
Note: Maximum Bandwidths of Different Multimode Fibers
OM1 – 62.5 um Core – 10GBit up to 33 meters, gigabit up to 300m
OM2 – 50 um Core – 10GBit up to 82 meters,gigabit up to 500m
OM3 – 50 um Core, Laser Optimized – 10GBit up to 300 meters,gigabit up to 1000m
OM4 – 50 um Core, Laser Optimized – 10GBit up to 550 meters,gigabit up to 1000m
OM1 – 62.5 um Core – 10GBit up to 33 meters, gigabit up to 300m
OM2 – 50 um Core – 10GBit up to 82 meters,gigabit up to 500m
OM3 – 50 um Core, Laser Optimized – 10GBit up to 300 meters,gigabit up to 1000m
OM4 – 50 um Core, Laser Optimized – 10GBit up to 550 meters,gigabit up to 1000m
Make To Order
Fiber Type | Fiber Standard | Fiber Count | Cable Type | Termination | Cable Length(m) | Breakout Length 1&2(Inches) | Breakout Termination | Polish Type |
OM4 OM3 OS1/2 OM2 OM1 | 12 Fibers | 8~144 Fibers | LSZH Bunch LSZH Ribbon Riser Bunch Riser Ribbon | First Connector: MTP Female MTP Male | 1~999 | 12~99 (36" is typical) | 3.0mm | UPC APC |
24 Fibers | 24~144 Fibers | Second Connector: LC Duplex/LC Simplex SC Duplex/SC Simplex ST Duplex/ST Simplex FC Duplex/FC Simplex | 0.9μm (standard) 2.0mm 3.0mm |
Note:Polishing connector (A): PC (multimode), APC 8° (single-mode)
Polishing connector (B) : PC (multimode/single-mode), APC 8° (single-mode)
Furcation length (B): 0.5m/0.3m for 1m total length
Type of protection connector: IP20
Patch cord Type: Minicore cable, round
Polishing connector (B) : PC (multimode/single-mode), APC 8° (single-mode)
Furcation length (B): 0.5m/0.3m for 1m total length
Type of protection connector: IP20
Patch cord Type: Minicore cable, round